Marine Generator Drawings: .

The links below will lead you to PDF’s of our Northern Lights generator sets and optional sound enclosures.

These files provide a good overview of a basic Northern Lights product, exclusive of options, transmissions, etc.  Because our products are intended to be customized for their optimal use on their respective applications, it is not possible to include all permutations of our products.  Please contact your local Northern Lights dealer or sales representative to learn more. 

Note that these drawings are intended for informational purposes only.  THEY ARE NOT TO BE USED FOR INSTALLATION.  Please contact Northern Lights’ Engineering Department for installation drawings.

Go To Older Models



M673L3
   
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
6.0 kW 5.0 kW Heat Exchanger

D-4449:
PDF

D-4462A:
PDF


M673LD3
   
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
5.0 kW 4.5 kW Heat Exchanger D-4449:
PDF
D-4462A:
PDF


M773LW3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
9.0 kW 7.0 kW Heat Exchanger

D-4481:
PDF

D-4463A:
PDF


M843NW3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
12 kW 10 kW Heat Exchanger D-4488 :
PDF

B-9904A:
PDF



M844W3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
16 kW 12 kW Heat Exchanger

C-6892:
PDF

C-6893:
PDF


M844LW3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
20 kW 16 kW Heat Exchanger C-6863A:
PDF
C-6860:
PDF


M864W3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
25 kW 20 kW Heat Exchanger

D-4530:
PDF

D-4565:
PDF


M944W3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
30 kW 26 kW Heat Exchanger D-4527:
PDF

D-4526A:
PDF



M944T
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
38 kW 32 kW Heat Exchanger D-4350B:
PDF
      D-4348D:
PDF


M1064D Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
40 kW 33 kW Heat Exchanger

D-4701:
PDF

D-4616A:
PDF
M1064D
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
40 kW 33 kW Heat Exchanger

D-3685B:
PDF (3ph & 1ph)

D-3690F:
PDF (with INSEP)

D-3938D:
PDF (with INSEP & Mounts)



M1064T1 Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
55 kW 50 kW Heat Exchanger

D-4649:
PDF

D-4616A:
PDF
M1064T1
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
55 kW 50 kW Heat Exchanger

D-3684C:
PDF

D-3690F:
PDF (with INSEP)

D-3938D:
PDF (with INSEP & Mounts)



M1064T2 Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
65 kW 55 kW Heat Exchanger

D-4649:
PDF

D-4616A:
PDF
M1064T2
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
65 kW 55 kW Heat Exchanger

D-3683B:
PDF (1ph)

D-3716B:
PDF (3ph)

D-3690F:
PDF (with INSEP)

D-3938D:
PDF (with INSEP & Mounts)



M1064A Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
92 kW 70 kW Heat Exchanger

D-4702:
PDF

D-4616A:
PDF
M1064A
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
92 kW 70 kW Heat Exchanger D-3682C:
PDF
(3 phase)

D-3690F:
PDF (with INSEP)

D-3938D:
PDF (with INSEP & Mounts)



M1064H Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
99 kW 90 kW Heat Exchanger D-4635:
PDF
D-4616A:
PDF
M1064H
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
99 kW 90 kW Heat Exchanger D-3674G:
PDF

D-3690F:
PDF (with INSEP)

D-3938D:
PDF (with INSEP & Mounts)

Wiring Diagram: OM2-4


M1066T
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
99 kW 80 kW Heat Exchanger D-4337:
PDF

D-4340:
PDF
(sound shield)

D-4341:
PDF
(sound shield with compound mounts)

D-4339:
PDF
(sound shield with alum base plate & compound mounts)

99 kW 80 kW Keel Cooled D-4338:
PDF

D-4340:
PDF
(sound shield)

D-4341:
PDF
(sound shield with compound mounts)

D-4339:
PDF
(sound shield with alum base plate & compound mounts)

 


M1066A1
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
130 kW n/a Heat Exchanger D-3764A:
PDF
(1& 3 phase)

D-3732C:
PDF

n/a
105 kW
Heat Exchanger

D-4281A:
PDF

D-3732C:
PDF



M1066A2 Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
145 kW n/a Heat Exchanger D-4656:
PDF
(3 phase)

D-4634A:
PDF

n/a 115 kW Heat Exchanger D-4656:
PDF
(3 phase)

D-4634A:
PDF



M1066A2
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
145 kW n/a Heat Exchanger D-3737B:
PDF
(3 phase)

D-3693C:
PDF

D-3732C:
PDF
(w/ compound mt)

n/a 115 kW Heat Exchanger D-4281A:
PDF
(3 phase)

D-3693C:
PDF

D-3732C:
PDF
(w/ compound mt)



M1066A3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
160 kW n/a Heat Exchanger D-3737B:
PDF
(3 phase) 

D-3732C:
PDF
(w/ compound mt)



M1066H Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
185 kW 155 kW Heat Exchanger D-4641:
PDF
(3 phase)

D-4634A:
PDF

Wiring Diagram: OM2-4



M1066H
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
185 kW 155 kW Heat Exchanger D-3708A:
PDF

D-3732C:
PDF



M1306A
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
355 - 400 kW 300 - 400 kW Heat Exchanger D-4640:
PDF

 

   



Previous Models Request Drawing
Click here to go previous models list. Click here to consult factory if you are unable to find the model you are looking for.
Back to the top
 
NOTICE: Northern Lights, Inc. continually updates and improves its product line. Dimensions and specifications are subject to change without notice. These drawings show common configurations of our product line. Some optional equipment changes the unit size envelope. If your application has critical size requirements, please check with your Northern Lights representative to confirm you have the most current drawing file.

 

 

 

           
 
home | Drawings | Marine Drawings
Northern Lights Marine GeneratorsLugger Propulsion Engines Technicold Marine Systems Clean-Sep Filtration System
 

| News | Training | Events | Application Reports | Affiliations | About us | Contact us | Site Map |

©2014 Northern Lights, Inc.