Northern Lights, Inc. Older Marine Drawings

 

The links below will lead you to PDF’s of our Northern Lights generator sets and optional sound enclosures.

These files provide a good overview of a basic Northern Lights product, exclusive of options, transmissions, etc.  Because our products are intended to be customized for their optimal use on their respective applications, it is not possible to include all permutations of our products.  Please contact your local Northern Lights dealer or sales representative to learn more.

Note that these drawings are intended for informational purposes only.  THEY ARE NOT TO BE USED FOR INSTALLATION.  Please contact Northern Lights’ Engineering Department for installation drawings.

M65T13
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing:
65 kW 50 kW Heat Exchanged D-4764:
PDF

(3 ph)
N/A (1 phase)

65 kW

(M65T13L/M50T13L)

50 kW Heat Exchanged D-4765:
PDF

(3 ph)
N/A (1 phase)
M673L3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
6.0 kW 5.0 kW Heat Exchanger D-4449:
PDF
D-4462A:
PDF
M673LD3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
5.0 kW 4.5 kW Heat Exchanger D-4449:
PDF
D-4462A:
PDF
M773LW3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
9.0 kW 7.0 kW Heat Exchanger D-4481:
PDF
D-4463A:
PDF
M843NW3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
12 kW 10 kW Heat Exchanger D-4488 :
PDF
B-9904A:
PDF
M844W3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
16 kW 12 kW Heat Exchanger C-6892:
PDF
C-6893:
PDF
M844LW3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
20 kW 16 kW Heat Exchanger C-6863A:
PDF
C-6860:
PDF
M864W3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
25 kW 20 kW Heat Exchanger D-4530:
PDF
D-4565:
PDF
M944W3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
30 kW 26 kW Heat Exchanger D-4527:
PDF
D-4526A:
PDF
M944T
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
38 kW 32 kW Heat Exchanger D-4350C:
PDF
      D-4348D:
PDF
M1064D Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
40 kW 33 kW Heat Exchanger D-4701:
PDF
D-4616A:
PDF
M1064D
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
40 kW 33 kW Heat Exchanger D-3685B:
PDF (3ph & 1ph)
D-3690F:
PDF (with INSEP)
D-3938D:
PDF (with INSEP & Mounts)
M1064T1 Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
55 kW 50 kW Heat Exchanger D-4649:
PDF
D-4616A:
PDF
M1064T1
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
55 kW 50 kW Heat Exchanger D-3684C:
PDF
D-3690F:
PDF (with INSEP)
D-3938D:
PDF (with INSEP & Mounts)
M1064T2 Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
65 kW 55 kW Heat Exchanger D-4649:
PDF
D-4616A:
PDF
M1064T2
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
65 kW 55 kW Heat Exchanger D-3683B:
PDF (1ph)D-3716B:
PDF (3ph)
D-3690F:
PDF (with INSEP)
D-3938D:
PDF (with INSEP & Mounts)
M1064T13R.2S
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
65 kW 55 kW D-4793:
PDF
D-3690F:
PDF (with INSEP)
D-3938D:
PDF (with INSEP & Mounts)
M1064A Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
92 kW 70 kW Heat Exchanger D-4702:
PDF
D-4616A:
PDF
M1064A
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
92 kW 70 kW Heat Exchanger D-3682C:
PDF
(3 phase)
D-3690F:
PDF (with INSEP)
D-3938D:
PDF (with INSEP & Mounts)
M1064H Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
99 kW 90 kW Heat Exchanger D-4635:
PDF
D-4616A:
PDF
M1064H
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
99 kW 90 kW Heat Exchanger D-3674H:
PDF
D-3690F:
PDF (with INSEP)
D-3938D:
PDF (with INSEP & Mounts)
Wiring Diagram: OM2-4
M1066T
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
99 kW 80 kW Heat Exchanger D-4337:
PDF
D-4340:
PDF
(sound shield)D-4341:
PDF
(sound shield with compound mounts)

D-4339:
PDF
(sound shield with alum base plate & compound mounts)

99 kW 80 kW Keel Cooled D-4338:
PDF
D-4340:
PDF
(sound shield)D-4341:
PDF
(sound shield with compound mounts)

D-4339:
PDF
(sound shield with alum base plate & compound mounts)

 

M1066A1
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
130 kW n/a Heat Exchanger D-3764A:
PDF
(1& 3 phase)
D-3732C:
PDF
n/a
105 kW
Heat Exchanger
D-4281A:
PDF
D-3732C:
PDF
M1066A2 Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
145 kW n/a Heat Exchanger D-4656:
PDF
(3 phase)
D-4634A:
PDF
n/a 115 kW Heat Exchanger D-4656:
PDF
(3 phase)
D-4634A:
PDF
M1066A2
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
145 kW n/a Heat Exchanger D-3737B:
PDF
(3 phase)
D-3693C:
PDF
D-3732C:
PDF
(w/ compound mt)
n/a 115 kW Heat Exchanger D-4281A:
PDF
(3 phase)
D-3693C:
PDF
D-3732C:
PDF
(w/ compound mt)
M1066A13
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
160 kW n/a Heat Exchanger D-4771:
PDF
M1066A3
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
160 kW n/a Heat Exchanger D-3737B:
PDF
(3 phase) 
D-3732C:
PDF
(w/ compound mt)
M1066H Low-Profile
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
185 kW 155 kW Heat Exchanger D-4641:
PDF
(3 phase)
D-4634A:
PDF
Wiring Diagram: OM2-4
M1066H
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
185 kW 155 kW Heat Exchanger D-3708A:
PDF
D-3732C:
PDF
M1306A
60 Hz / 1800 rpm: 50 Hz / 1500 rpm: Cooling Type: Generator Drawing: Enclosure Drawing:
355 – 400 kW 300 – 400 kW Heat Exchanger D-4640:
PDF
<

NOTICE: Northern Lights, Inc. continually updates and
improves its product line. Dimensions and specifications are subject to
change without notice. These drawings show common configurations of our
product line. Some optional equipment changes the unit size envelope.
If your application has critical size requirements, please check with
your Northern Lights representative to confirm you have the most current
drawing file.
© Northern Lights, Inc. 2017