Low-Profile Package
More installation flexibility
The low-profile configuration concentrates generator capacity into a reduced-height package, giving installers more flexibility when vertical machinery-space clearance is limited.

M65T13SL is designed for vessels that need 65 kW of generator capacity without giving up unnecessary vertical machinery-space clearance. Its turbocharged industrial engine, replaceable wet liners, high-pressure common-rail fuel system, and gear-driven seawater pump combine durable construction with practical long-term serviceability.
| Specification | 60 Hz | 50 Hz |
|---|---|---|
| Rated Power (kW) | 65 | 55 |
| RPM | 1800 | 1500 |
| Frequency (Hz) | 60 | 50 |
| Phase (PF) Standard | 3 Phase (0.8 PF) | |
| Cylinders | 4 | |
| Cycle | 4 | |
| Displacement | 276 cu in4.5 L | |
| Bore | 4.19 in106 mm | |
| Stroke | 5 in127 mm | |
| Aspiration | Turbocharged | |
| Specification | 60 Hz | 50 Hz |
|---|---|---|
| Air Consumption (CFM)Air Consumption (m³/min) | 2156.1 | 1484.2 |
| Exhaust Gas Volume (CFM)Exhaust Gas Volume (m³/min) | 52114.7 | 37110.5 |
| Max Exhaust Back Pressure | 30 in H₂O762 mm H₂O | |
| Wet Exhaust Elbow OD | 4 in102 mm | |
| Length | 75 in1905 mm | |
| Width | 38 in965 mm | |
| Height | 37.8 in960 mm | |
| Dry Weight | 2594 lbs1177 kg | |
| Standard Voltage | 12V | |
| Optional Voltage | 24V | |
| Min Battery Capacity (Ah) | 200 | |
| Min Battery CCA (12V) | 1100 | |
| Starter Current (12V) | 920 A | |
| Min Battery CCA (24V) | 750 | |
| Starter Current (24V) | 600 A | |
| Battery Cable Size | 2/0 | |