Specifications + Dimensions

ModelRC08
BTU @ 60 HZ (50 HZ)8,000 (6,600)
AMP Draw 115V (230V)8.9 (4.4)
Dimensions: HxWxD in. (mm)14 (355.6) x 10 (254) x 14 (355.6)
Weight: Lbs (kg)59 (26.79)
ModelRC12
BTU @ 60 HZ (50 HZ)12,000 (10,000)
AMP Draw 115V (230V)n/a (5.9)
Dimensions: HxWxD in. (mm)14 (355.6) x 10 (254) x 14 (355.6)
Weight: Lbs (kg)64 (29.06)
ModelRC16
BTU @ 60 HZ (50 HZ)16,000 (13,250)
AMP Draw 115V (230V)15 (6.2)
Dimensions: HxWxD in. (mm)14 (355.6) x 10 (254) x 14 (355.6)
Weight: Lbs (kg)66 (29.96)
ModelRC24
BTU @ 60 HZ (50 HZ)24,000 (20,000)
AMP Draw 115V (230V)n/a (12)
Dimensions: HxWxD in. (mm)17 (431.8) x 15.25 (387.3) x 26.5 (673.1)
Weight: Lbs (kg)120 (54.48)
ModelRC32
BTU @ 60 HZ (50 HZ)32,000 (26,500)
AMP Draw 115V (230V)n/a (16.5)
Dimensions: HxWxD in. (mm)17 (431.8) x 15.25 (387.3) x 26.5 (673.1)
Weight: Lbs (kg)128 (58.11)
ModelRC40
BTU @ 60 HZ (50 HZ)40,000 (33,000)
AMP Draw 115V (230V)n/a (22.5)
Dimensions: HxWxD in. (mm)17 (431.8) x 15.25 (387.3) x 26.5 (673.1)
Weight: Lbs (kg)130 (59.02)
ModelRC48
BTU @ 60 HZ (50 HZ)48,000 (40,000)
AMP Draw 115V (230V)n/a (22.7)
Dimensions: HxWxD in. (mm)16.8 (426.7) x 15.75 (400) x 26.5 (673.1)
Weight: Lbs (kg)149 (67.65)
ModelRC60
BTU @ 60 HZ (50 HZ)60,000 (50,000)
AMP Draw 115V (230V)n/a (26)
Dimensions: HxWxD in. (mm)18.71 (475.2) x 15.75 (400) x 26.5 (673.1)
Weight: Lbs (kg)152 (69.01)

Note:

Information and dimensions are subject to change without notice.

Downloads

Features + Benefits

  • Single pass fluted coaxial copper-nickel counter flow condenser allows low sea water velocity while providing maximum efficiency and even condensing.
  • High and low charging ports easily accessible.
  • Wiring covered with fire resistant sheathing.
  • 316L grade stainless steel chassis, fasteners and hardware.
  • Rubber vibration compressor isolation mounting feet.
  • Small overall size.
  • Two-part urethane paint system.
© Northern Lights, Inc. 2018